Data Centre Specs

Our Data Centre

Our state of the art servers are governed only by German law (especially the data protection law, BGB and HGB) and are located in ultra-modern “green data centers“ in one of Germany’s highly awarded data centers for dedicated and colocation services. With one in Munich and a second one in Nuremberg the focus is always on operational safety and energy efficiency. Both data centers are in different cities being several hundred kilometers apart from each other, and both are powered by different electricity suppliers (SWM and N-Ergie). Due to this geographical redundancy your services will stay online even if it comes to the highly unlikely case that one data center will be damaged by fire, water, or any other imaginable disaster.
DATA CENTRE FACTS

We have located in Germany due to the fact that nowhere in the world are there stricter requirements for data protection and privacy than in the European Union – and within the Union, no other country stands for data protection more than Germany. 

Location: Munich – Germany
Nuremberg – Germany
Data center area: 300 m² (Munich)
1750 m² (Nuremberg)
Air conditioning: Multiple chillers (n+1)
Groundwater cooling system
Several climate cabinets (n+1)
100 % redundant
Free cooling
Energy-efficient
Remote-controlled
Expandable
Internet access:

Carrier-neutral

Numerous different fiber carriers using at least two different fiber directions into the building

The data centers are currently connected to the Internet with 200 Gbit/s:
– CenturyLink: 60 Gbit/s
– Telia Carrier: 60 Gbit/s
– Versatel: 20 Gbit/s
– DE-CIX: 20 Gbit/s
– AMS-IX: 20 Gbit/s
– M-NET: 10 Gbit/s
– Colt: 10 Gbit/s

Energy supply: Inhouse transformer-station
Multiple UPS with batteries (n+1)
Emergency backup generator with powerful diesel generator
Security: Access only via ID card
Alarm system
Security service on duty
More than 50 observation cameras and video recording
Several live-webcams
Smoke detector / automatic fire alarm
Smoke exhaust installation
Water detector
Environment:

Hundreds of power outlets per room, mounted directly into the double floor

Every single power outlet electrically interlocked at 16 A

Cable bushings mounted into the double floor next to the power outlets

Completely locked double floor
AC ventilation grills, individually adjustable, mounted into the double floor

Cool water canalization only beneath the double floor

Gullies for the case of a pipe leakage

19”-Racks individually lockable

Cages, entire colocation rooms for single customers and individual modifications/equipment available

Satellite feed (Astra 19.2°E and Eutelsat Hot Bird 13.0°E)

Service: Personnel on site 365 days a year, also on holidays and weekends. Priority and emergeny support available